Whārangi-1 o te haki KCO-Fiver-MTP-MPO-QSFP

SFP+/QSFP

SFP me QSFP
SFP QSFP
Ka whakamahia e te taputapu whakawhiti SFP (Small Form-factor Monoggable) tētahi hongere kotahi hei tuku me te whiwhi raraunga. Ka honoa e te QSFP (Quad Small Form-factor Pluggable) ngā hongere e whā ki roto i te kōwae kotahi hei whakatutuki i te whānui o te whānui e whā ngā wā.
SFP (1 Ara): He iti noa te wāhi me te kotahi ara mō te tuku (Tx) me te whiwhi (Rx). Ko te tikanga, ka whakamahia he hononga LC duplex, SC simplex rānei. QSFP (4 Ara): He whānui ake te tapuwae. E whā ngā hongere tuku motuhake me ngā hongere whiwhi motuhake e whā kei roto. I te nuinga o te wā ka whakamahia he hononga MPO/MTP kiato-teitei (mō ngā whatu whakarara) he multiplexer ā-roto rānei i runga i te LC duplex (mō te Wavelength Division Multiplexing).
Āhua Āhua Ngā Reiti Raraunga Matua Paerewa Noa / Momo Ngā Whakamahinga Noa
SFP 1 Gbps 1G SFP Ngā hononga hinonga tawhito
SFP+ 10 Gbps 10G SFP+ Ngā kaupapa matua o te hinonga hou
SFP28 25 Gbps 25G SFP28 5G FTTA / Ngā pokapū raraunga
SFP56 50 Gbps 50G SFP56 Rorohiko ahokore waenga-haerenga, motuhake
QSFP+ 40 Gbps (4 x 10G) 40G Pūtake-SR4 / LR4 Ngā paparanga tohatoha umanga
QSFP28 100 Gbps (4 x 25G) 100G Turanga-SR4 / LR4 Ngā papanga rau-tuarā o te pokapū raraunga
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Ngā taupū AI me ngā hanganga kapua
KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Hononga Whakawhiti me te DDM

KCO QSFP+ 40G SR4 40Gb/s QSFP+ MMF 100M MPO Hononga Whakawhiti me te DDM

Te Kaha o te Hongere: 40 Gbps mō ia kōwae

Te tere raraunga tae atu ki te 11.1Gbps mō ia hongere

Te roanga hononga mōrahi o ngā hononga 100m i runga i te muka maha-aratau OM3. Ngā hononga 150m rānei i runga i te muka maha-aratau OM4.

Hangarau VCSEL 850nm Pono Teitei

Ka taea te mono i te hiko

Āhei ki te tātaritanga mamati SFF-8436

Awhe pāmahana whakahaere o te pouaka: 0°C ki te 70°C

Te tohatoha hiko < 0.7 W

KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Whakawhiti Whatu

KCO QSFP28 100G ER4 ER4L-S SMF 1310nm 40km WDM LC 100Gb/s QSFP28 ER4 SMF 1310nm WDM DLC Whakawhiti Whatu

+ Ka whakauruhia e te taputapu whakawhiti muka whatu KCO QSFP28 100G ER4 te ara o te kaiwhiwhi me te tuku ki te kōwae kotahi. I te taha tuku, e whā ngā ara o ngā rerenga raraunga raupapa ka whakahokia mai, ka whakahoutia te wā, ka tukuna ki ngā taraiwa taiaho e whā.

+ Ka whakahaerehia e ngā taraiwa taiaho te 4-EML me te roangaru waenga o te 1296 nm, 1300nm, 1305nm me te 1309 nm.

KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 Whakawhiti muka aratau kotahi LR4

KCO QSFP28 100G LR4 SMF 1310 10km DOM LC 100Gb/s QSFP28 Whakawhiti muka aratau kotahi LR4

KCO QSFP28 100G LR4Ka whakauruhia e te Pūwhakawhitiwhiti Whatu te ara o te kaiwhiwhi me te tuku raraunga ki te kōwae kotahi. I te taha tuku, e whā ngā ara o ngā rerenga raraunga raupapa ka whakahokia mai, ka whakahoutia te wā, ka tukuna ki ngā taraiwa taiaho e whā.

Ka whakahaerehia e ngā taraiwa taiaho te Taiaho Urupare Tohatoha-4 (DFB) me ngā roangaru pokapū o te 1296 nm, 1300nm, 1305nm me te 1309 nm. Ka whakareatia ngā tohu whatu ki tētahi muka aratau-kotahi mā te hononga LC paerewa ahumahi.

100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO Kaituku Whatunga

100G QSFP28 PSM4 SMF 1310nm 2KM MTP MPO Kaituku Whatunga

- P/N:KCO-QSFP28-100G-PSM4

- Tae atu ki te 26Gbps mō ia hongere whānui;

- E tutuki ana ki te QSFP28 MSA

- 4 ngā hongere 1310nm DFP

- 4 ngā hongere pūoko whakaahua PIN

- Tae atu ki te 2km te toro atu i runga i te muka aratau kotahi paerewa

- Hototahi ki te hononga MTP MPO

- Atanga hiko wera-mono

- Te whakahaere i te pūhiko hiko kotahi +3.3V

- Te awhe pāmahana arumoni 0°C ki te 70°C

- E tutuki ana i ngā whakaritenga IEEE 802.3ba mō ngā hononga 100GBASE-PSM4

- Wāhanga e tutuki ana i te RoHS

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Whakawhiti muka whatu

KCO QSFP28 100G ZR4 SMF 1310nm 80km WDM LC Whakawhiti muka whatu

Kua hangaia te KCO QSFP28 100G ZR4 mō ngā tono whakawhitiwhiti kōrero whatu 80km.

Kei roto i tēnei kōwae he tuku whatu ara-4, he kaiwhiwhi whatu ara-4 me te poraka whakahaere kōwae tae atu ki te atanga raupapa waea-2.

Ka whakareatia ngā tohu whatu ki tētahi muka aratau-kotahi mā tētahi hononga LC paerewa ahumahi.

Pūwae Whakawhiti Whatu LC/UPC MMF 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Duplex Hototahi Cisco

Pūwae Whakawhiti Whatu LC/UPC MMF 100GBASE-SR SWDM4 QSFP28 BiDi 850/880/910/940nm 100m DOM Duplex Hototahi Cisco

KCO QSFP28100G SRBD MMF 100M LC Duplex DOM

Pūrere Whakawhiti Whatu Aronga-rua 100GBASE-SR SWDM4 QSFP28 Hototahi ki Cisco mō te Ethernet me te Pokapū Raraunga (MMF, 850/880/910/940nm, 100m, LC, DOM)

Pūwae Whakawhiti Whatu MMF 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC Hototahi Cisco, Wehenga ki te 4 x 25G-SR me te DDM

Pūwae Whakawhiti Whatu MMF 100GBASE-SR4 QSFP28 850nm 100m DOM MPO-12/UPC Hototahi Cisco, Wehenga ki te 4 x 25G-SR me te DDM

Te tere raraunga tae atu ki te 27.952 Gbps mō ia hongere

Te roanga hononga mōrahi o te 150m i runga i te muka maha-aratau OM4

Hangarau VCSEL 850nm Pono Teitei

Ka taea te mono i te hiko

Āhei ki te tātaritanga mamati SFF-8636

E tutuki ana ki te QSFP28 MSA

Awhe pāmahana whakahaere o te pouaka: 0°C ki te 70°C

Te whakamararatanga hiko < 2.0W

KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Kaituku Whakawhiti Muka Whatu 200G-FR4H OSFP SMF Duplex LC 2km

KCO QSFP56 200G FR4 S SMF 2km DLC QSFP56 Kaituku Whakawhiti Muka Whatu 200G-FR4H OSFP SMF Duplex LC 2km

- Tae atu ki te 50Gbps te tere raraunga mō ia hongere mā te whakarerekētanga PAM4

- 4 ngā tuku me ngā kaiwhiwhi o ngā hongere takirua

- Ngā huinga CWDM LD me PD kua whakauruhia

- He rite te hononga hononga LC/UPC takirua ki te atanga

- Pūnaha hiko kotahi +3.3V 6, kua whakatinanahia te mahi DDM

- Tauira āhua QSFP56 ka taea te mono-wera

- Te roanga hononga mōrahi o te 2km mā te muka SMF

- Te iti o te tohatoha mana: <6.5W

- He tiwhikete haumaru taiaho akomanga 1 o te ao

- Awhe pāmahana whakahaere: 0~ +70

- E tutuki ana i ngā whakaritenga ROHS

KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Ngā Whakawhitiwhiti Muka Whatu

KCO QSFP56 200G LR4 S SMF 1310nm 10km DOM DLC 200GBASE-LR4 QSFP56 1310nm 10km DOM Duplex LC SMF Ngā Whakawhitiwhiti Muka Whatu

- E tutuki ana i te 200GBASE-LR4, 4x 26.5625 GBd PAM4

- E tutuki ana i te 200GAUI-4, 4x 26.5625 GBd PAM4

- Tauira āhua QSFP56 ka taea te mono-wera

- E tutuki ana i te QSFP+ 28 Gb/s

- Ko te roanga mōrahi o te hononga he 10km mā SMF

- Hononga LC takirua

- Te iti o te tohatoha hiko: <8.0W

- Awhe pāmahana whakahaere: 0 ki te 70ºC

KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver

KCO QSFP56 200G SR4 S MMF MPO-12 100m 200Gbps QSFP56 OSFP Multimode 100m MTP MPO Fiber Optic Transceiver

- Pūwhakawhiti QSFP56 Wera Monokia

- Tautoko ana i te tere moka whakakotahi 212,5Gbps

- Tae atu ki te 53.125Gbps te tere raraunga mō ia hongere

- Tauranga QSFP56 e tutuki ana i te SFF-8665;

- Whakahaere I2C e tutuki ana i te SFF-8636

- E tutuki ana ki te IEEE802.3cd 200GBASE-SR4

- Pūtake hononga MPO-12 me te mata pito UPC

- Te roanga hononga mōrahi o te 100m i runga i te OM4 MMF

- Pūnaha Hiko Kotahi 3.3V

- He iti te horapa o te mana (<4.5W)

- Awhe pāmahana o te pouaka whakahaere: 0°C ki te 70°C

- E tutuki ana i ngā whakaritenga RoHS

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

KCO-QDD-400G-SR8-S MMF 850nm 100m DOM MPO-16/APC

Wehenga Hototahi 400GBASE-SR8 QSFP-DD Optical Transceiver Module ki te 2 × 200G-SR4 me te 8 × 50G-S

- Tauira āhua QSFP-DD ka taea te mono wera

- Tautoko ana i te tere moka whakakotahi 400Gb/s

- Tae atu ki te 53.125Gbps te tere raraunga mō ia hongere

- Te roanga hononga mōrahi o te 70m i runga i te OM3 me te 100m i runga i te OM4

- Putanga hononga MPO

- Awhe pāmahana o te pouaka: 0 ~ +70

- Te tohatoha hiko: <10W

- Pūnaha hiko kotahi 3.3V

- Kua Whakamanahia te Hototahi i roto i te Whatunga Arista/NVIDIA/Cisco RoCE

- Te Whānuitanga o te Aratuku Teitei

- Te Whakaroa Iti

- E tutuki ana i ngā whakaritenga a te QSFP-DD MSA

- E tutuki ana ki te IEEE 802.3cd

- Amui RoHS

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

KCO QDD 400G FR S 4*100G PAM4 SMF 1310nm 2KM MPO-12 QDD-4x100G-FR-S

Taputapu muka whatu 400GBASE-FR QSFP-DD 4*100G PAM4 Hototahi 1310nm 2Km DOM MPO-12/APC

- E tutuki ana i te QSFP-DD MSA

- Hononga MPO-12 me te mata pito koki 8°

- Te whakapaunga hiko <11 W

- Te pāmahana o te pouaka whakahaere 0 ki te 70 ºC

- Atanga whakahaere CMIS 4.0

- Aratau Wehenga • 4x tutuki i te 100GBASE-FR1 53.125GBd PAM4 • 100GAUI-2 tutuki i te 2x 26.5625 GBd PAM4

- Aratau Whakakotahi • E tutuki ana i te 400GBASE-FR4 4x 53.125GBd PAM4 • E tutuki ana i te 400GAUI-8 8x 26.5625 GBd PAM4

<< < O mua123Panuku >>> Whārangi 2 / 3

Te whakamahinga o te SFP me te QSFP i runga i te FTTH me te otinga FTTA

Inenga Hoahoa FTTH (Muka-ki-te-Kāinga) FTTA (Muka-ki-te-Pūihi)
Kōwae Tapa (SFP) GPON / XGS-PON SFP (Simplex SC) 25G SFP28 eCPRI (Duplex, BiDi LC rānei)
Kōwae Matua (QSFP) Ngā Hononga Whatunga QSFP28 / QSFP-DD Ngā Putanga Reo Irirangi QSFP28 Port-ki-SFP28
Kawa Matua Whakatakotoranga Ethernet / ATM CPRI (4G) / eCPRI (5G kua whakakīia)
Whakaritenga Pāmahana Arumoni (0°C ki te 70°C) i roto i te CO Ahumahi (-40°C ki te 85°C) ki runga i te pou
Whakamahinga [ Tari Matua OLT ] ===( Hononga Upload QSFP )===> [ Pātene Matua ]
|
( PON SFP )
|
[ Waahanga Hangū ] ——> [ Kāinga ONT / ONU ]
[ Pūnaha BBU / DU ] ===( QSFP28 Breakout )===> [ 4x SFP28 Ports Tower ]
||
(Pūtake Poutū)
||
[ 25G SFP28 RRU ]
Ka whakawhirinaki nui ngā whatunga FTTH ki ngā āhuahanga Whatunga Whatu Āhuakore (PON) hei tohatoha i te ipurangi mai i te Tari Matua (CO) ki ngā kāinga takitahi. Ko te Paerewa SFP28 (25G): Ka whakahaerehia ngā pūtau Macro 5G hou i runga i ngā transceiver 25G SFP28 i hangaia mō ngā kawa eCPRI (Enhanced Common Public Radio Interface).
Taha OLT: Ka whakamahia e te anga Optical Line Terminal (OLT) ngā kōwae PON SFP motuhake (GPON, XGS-PON, 25G-PON rānei). He ahurei ēnei nā te mea he BiDi (Bidirectional) simplex SFPs—e whakamahi ana i te hononga SC kotahi hei tuku i runga i te roangaru kotahi (hei tauira, 1490nm) me te whiwhi i runga i tētahi atu (hei tauira, 1310nm) hei mahi ki te 32, ki te 64 rānei ngā kāinga i runga i te kotahi miro muka. Te Whakapakari Ahumahi: Me whai pāmahana Ahumahi (-40°C ki te 85°C) ngā SFT e whakatakotoria ana ki runga i te pourewa kia ora ai i ngā huarere tino kino o te wā. Ka whakauruhia ki roto i ngā whare pakari o waho pēnei i a FullAXS, ODVA rānei i mua i te mono tika atu ki te Wāhanga Reo Irirangi Mamao (RRU).
Taha ONT/ONU: He maha ngā wā ka whakamahia e te whatunga whatu taha-kiritaki i roto i te kāinga, i te pakihi rānei ngā kōwae 1G SFP paerewa, 10G SFP+ rānei kua monohia ki te kuwaha kāinga. BiDi me te CWDM: Hei penapena i te taumaha me ngā rauemi muka i runga i te rawa pourewa, he maha ngā wā ka whakamahia e ngā tohunga hangarau ngā kōwae BiDi SFP28, CWDM SFP28 rānei, kia iti ake ai ngā aho karāhe e tohatohahia ana e ngā roopu auau maha.
Te Whakamahinga QSFP (Te Matua o te Tari Matua: Kāore ngā kaiwhakamahi kāinga e whakamahi i ngā kōwae QSFP. Engari, ka whakamahia ngā pūwhakawhiti QSFP28 (100G) QSFP-DD rānei (400G/800G) i roto i te Tari Matua. Ka kohikohia e rātou te nui o ngā waka e puta mai ana i ngā kāri raina PON SFP maha, ka tukuna ki runga ki te matua ipurangi whānui. Ngā Whakatakotoranga Pakaru: Engari mō te whakahaere i ngā taura SFP takitahi e 24, ka whakamahia e te pouara turanga matotoru-teitei ngā tauranga QSFP28 (100G) i te aratau pakaru. Ka honoa he tauranga QSFP28 kotahi ki te taura pūtake MPO pakaru 1-ki-4, ka tuku pai i ngā hongere eCPRI 25G motuhake e whā tae atu ki ngā reo irirangi pourewa motuhake e whā.

Tukanga
Tukanga
Tukanga