Whārangi-1 o te haki KCO-Fiver-MTP-MPO-QSFP

SFP+/QSFP

SFP me QSFP
SFP QSFP
Ka whakamahia e te taputapu whakawhiti SFP (Small Form-factor Monoggable) tētahi hongere kotahi hei tuku me te whiwhi raraunga. Ka honoa e te QSFP (Quad Small Form-factor Pluggable) ngā hongere e whā ki roto i te kōwae kotahi hei whakatutuki i te whānui o te whānui e whā ngā wā.
SFP (1 Ara): He iti noa te wāhi me te kotahi ara mō te tuku (Tx) me te whiwhi (Rx). Ko te tikanga, ka whakamahia he hononga LC duplex, SC simplex rānei. QSFP (4 Ara): He whānui ake te tapuwae. E whā ngā hongere tuku motuhake me ngā hongere whiwhi motuhake e whā kei roto. I te nuinga o te wā ka whakamahia he hononga MPO/MTP kiato-teitei (mō ngā whatu whakarara) he multiplexer ā-roto rānei i runga i te LC duplex (mō te Wavelength Division Multiplexing).
Āhua Āhua Ngā Reiti Raraunga Matua Paerewa Noa / Momo Ngā Whakamahinga Noa
SFP 1 Gbps 1G SFP Ngā hononga hinonga tawhito
SFP+ 10 Gbps 10G SFP+ Ngā kaupapa matua o te hinonga hou
SFP28 25 Gbps 25G SFP28 5G FTTA / Ngā pokapū raraunga
SFP56 50 Gbps 50G SFP56 Rorohiko ahokore waenga-haerenga, motuhake
QSFP+ 40 Gbps (4 x 10G) 40G Pūtake-SR4 / LR4 Ngā paparanga tohatoha umanga
QSFP28 100 Gbps (4 x 25G) 100G Turanga-SR4 / LR4 Ngā papanga rau-tuarā o te pokapū raraunga
QSFP56 200 Gbps (4 x 50G) 200G FR4 / DR4 Ngā taupū AI me ngā hanganga kapua
KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Module Whakawhiti Whatu, Wehenga ki te 4 x 100G-DR

KCO-QDD-400G-DR4 400GBASE-DR4 QSFP-DD PAM4 1310nm 500m DOM MPO-12/APC SMF Module Whakawhiti Whatu, Wehenga ki te 4 x 100G-DR

- E tutuki ana ki te QSFP-DD MSA

- Ngā Ara Whatu Whakarara 1310nm e Whā

- E tutuki ana ngā whakaritenga IEEE 802.3bs 400GBASE-DR4

- E tutuki ana i ngā whakaritenga RoHS

- Tukunga tae atu ki te 500m i runga i te SMF me te FEC

- 8×53. 125Gb/s Atanga Hiko (400GAUI-8)

- Atanga Whatu Tere Raraunga 4* 106.25Gbps (PAM4)

- Awhe pāmahana o te pouaka: 0 ki te 70C

- Te Whakamahinga Mana Mōrahi 10W

- Hononga MPO-12

- Ngā Mahi Tātaritanga Mamati Kua Hangaia

KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Module Whakawhiti Whatu

KCO-QDD-400G-LR4-S 400GBASE-LR4 QSFP-DD PAM4 1310nm 10km DOM Duplex LC/UPC SMF Module Whakawhiti Whatu

- E tutuki ana i ngā whakaritenga a te QSFP-DD MSA

- 4 ngā ara CWDM, hoahoa MUX/DEMUX

- Hononga LC takirua

- Tuku tae atu ki te 10km i runga i te muka aratau kotahi (SMF) me te FEC

- Atanga hiko 8×53.125Gb/s (400GAUI-8)

- Tere Raraunga 106.25Gbps (PAM4) mō ia hongere

- Awhe pāmahana o te pouaka: 0 ~ +70

- Te kaha mōrahi e pau ana 9W

- Amui RoHS

400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Module Whakawhiti Whatu, Wehenga ki te 4 x 100G-SR1.2

400GBASE-SR4.2 QSFP-DD PAM4 850nm 100m DOM MPO-12/UPC MMF Module Whakawhiti Whatu, Wehenga ki te 4 x 100G-SR1.2

- QSFP-DD MSA

- 8x 53.125Gb/s Atanga Hiko (400GAUI-8) e tutuki ana

- Tuku OM5 MMF tae atu ki te 150m

- Hononga Whatu MPO-12

- E tutuki ana i ngā whakaritenga RoHS

- Pūnaha Hiko Kotahi 3.3 V

- Te Whakamahinga Mana Mōrahi 12W

- Te pāmahana o te pouaka whakahaere: 0°C ki te 70°C

800GBASE 2xSR4/SR8 OSFP Finned Top PAM4 850nm 50m DOM Takirua MPO-12/APC MMF Pūwae Whakawhiti Whatu

800GBASE 2xSR4/SR8 OSFP Finned Top PAM4 850nm 50m DOM Takirua MPO-12/APC MMF Pūwae Whakawhiti Whatu

- Hototahi ki a Cisco OSFP-800G-VR8

- Hototahi ki te NVIDIA/Mellanox MMA4Z00-NS

- Hototahi ki te Arista Networks OSFP-800G-2VSR4

- Hototahi ki te Juniper Networks OSFP-2X400G-VR4-P

- Hototahi ki te H3C OSFP-800G-VR8-MM850-DMPO

-Ētahi atu

800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Takirua MPO-12/APC SMF Pūwae Whakawhiti Whatu Muka

800GBASE 2xDR4/DR8 OSFP Finned Top PAM4 1310nm 500m DOM Takirua MPO-12/APC SMF Pūwae Whakawhiti Whatu Muka

Hototahi ki NVIDIA/Mellanox MMS4X00-NM

Ko te Cisco OSFP-800G-DR8 e hototahi ana

Juniper Networks Hototahi ki te OSFP-2X400G-DR4-P

Hototahi ki te H3C OSFP800-800G-DR8-SM1310-DMPO

Pouara whatunga muka whatu FTTH Huawei HG8546M GPON ONU 4LAN 1 Reo WIFI 2 Pūihi GPON ONU

Pouara whatunga muka whatu FTTH Huawei HG8546M GPON ONU 4LAN 1 Reo WIFI 2 Pūihi GPON ONU

Ko te EchoLife HG8546M, he waeine whatunga whatu (ONU), he kuaha kāinga kounga teitei i roto i te otinga FTTH Huawei. Mā te whakamahi i te hangarau GPON, ka whakaratohia he urunga whānui-rahi mō ngā kaiwhakamahi kāinga me SOHO. Ka whakaratohia e te H8546M he tauranga POTS kotahi, he tauranga Ethernet urutau-aunoa GE kotahi+3 FE, me te tauranga Wi-Fi e rua. Kei te H8546M ngā āheinga tuku whakamua mahi-teitei hei whakarite i te wheako pai ki ngā ratonga VoIP, Ipurangi me te ataata HD. Ka whakaratohia e te H8546M he otinga pūrua tino pai me ngā āheinga tautoko ratonga e aro ana ki te heke mai mō te whakatinanatanga FTTH.

1GE +1FE EPON XPON GPON GEPON HG8310 Wāhanga Whatunga Whatu Muka ONU ONT

1GE +1FE EPON XPON GPON GEPON HG8310 Wāhanga Whatunga Whatu Muka ONU ONT

- Kua hangaia ngā raupapa EPON ONT hei otinga FTTH hononga HGU (HomeGatewayUnit). – Mā te tono FTTH karaehe-kaikawe e whakarato te urunga ratonga raraunga. – Ko te raupapa EPON ONT e hangai ana ki te hangarau XPON pakari, pumau, utu-whai hua. – Ka taea te huri aunoa me te EPON me te GPON ina uru atu ki te EPON OLT, ki te GPON OLT rānei. – Ka whakamahia e te raupapa EPONONT te pono teitei, te whakahaere ngāwari, te ngāwari whirihoranga me te kounga pai o te ratonga (QoS) e whakamana ana i te whakatutuki i te mahi hangarau o te kōwae o China Telecom EPON CTC3.0 me te Paerewa GPON o ITU-TG.984.X

Kaitahuri Pāpāho Muka Whatu 10/100M

Kaitahuri Pāpāho Muka Whatu 10/100M

- He kaitahuri pāpāho urutau 10/100Mbps te kaitahuri pāpāho muka whatu.

- Ka taea e ia te whakawhiti i ngā tohu hiko 100Base-TX ki ngā tohu whatu 100Base-FX.

- Ka Whiriwhiri Aunoa te atanga hiko ki te tere Ethernet 10Mbps, 100Mbps rānei, kāore he whakarerekētanga.

- Ka taea e ia te whakaroa i te tawhiti tuku mai i te 100m ki te 120km mā roto i ngā taura parahi.

- Kua whakaratohia ngā tohu LED hei tirotiro tere i te āhua o te mahi a ngā taputapu.

- He maha atu anō hoki ngā painga pēnei i te tiakitanga motuhake, te haumarutanga raraunga pai, te pumau o te mahi me te ngāwari o te tiaki.

- Whakamahia te urutau hiko o waho.

- Huinga Mamati: IC+ IP102

8 16 tauranga c++ gpon 5608T OLT

8 16 tauranga c++ gpon 5608T OLT

Kua hangaia te MA5608T Mini OLT hei aro atu ki ngā āhuatanga whakatinanatanga muka-ki-te-papa (FTTP) me ngā āhuatanga whakatinanatanga muka hohonu, ina kore pea e pai te uru o tētahi anga OLT nui mō ngā take maha. Kua hangaia te mini OLT MA5608T a Huawei hei tāpiri tino pai ki ētahi atu OLT nui ake o te raupapa MA5600, ā, he rite tonu ngā āhuatanga me te mahi o te taumata kawe. Nā te hoahoa kiato me te urunga ki mua o te MA5608T, he otinga pai mō te whakatinanatanga ki ngā wāhi pēnei i ngā whare iti te wāhi, ngā kāpata o waho, ngā rūma o raro rānei. He kōwhiringa hiko AC me DC tōna, he whānuitanga pāmahana whānui, ā, he ngāwari te tāutanga.

SFP+ -10G-LR

SFP+ -10G-LR

• Kaiwhakawhiti SFP+ 10Gb/s

• Ka taea te mono wera, LC takirua, +3.3V, 1310nm DFB/PIN, Aratau takitahi, 10km

Te whakamahinga o te SFP me te QSFP i runga i te FTTH me te otinga FTTA

Inenga Hoahoa FTTH (Muka-ki-te-Kāinga) FTTA (Muka-ki-te-Pūihi)
Kōwae Tapa (SFP) GPON / XGS-PON SFP (Simplex SC) 25G SFP28 eCPRI (Duplex, BiDi LC rānei)
Kōwae Matua (QSFP) Ngā Hononga Whatunga QSFP28 / QSFP-DD Ngā Putanga Reo Irirangi QSFP28 Port-ki-SFP28
Kawa Matua Whakatakotoranga Ethernet / ATM CPRI (4G) / eCPRI (5G kua whakakīia)
Whakaritenga Pāmahana Arumoni (0°C ki te 70°C) i roto i te CO Ahumahi (-40°C ki te 85°C) ki runga i te pou
Whakamahinga [ Tari Matua OLT ] ===( Hononga Upload QSFP )===> [ Pātene Matua ]
|
( PON SFP )
|
[ Waahanga Hangū ] ——> [ Kāinga ONT / ONU ]
[ Pūnaha BBU / DU ] ===( QSFP28 Breakout )===> [ 4x SFP28 Ports Tower ]
||
(Pūtake Poutū)
||
[ 25G SFP28 RRU ]
Ka whakawhirinaki nui ngā whatunga FTTH ki ngā āhuahanga Whatunga Whatu Āhuakore (PON) hei tohatoha i te ipurangi mai i te Tari Matua (CO) ki ngā kāinga takitahi. Ko te Paerewa SFP28 (25G): Ka whakahaerehia ngā pūtau Macro 5G hou i runga i ngā transceiver 25G SFP28 i hangaia mō ngā kawa eCPRI (Enhanced Common Public Radio Interface).
Taha OLT: Ka whakamahia e te anga Optical Line Terminal (OLT) ngā kōwae PON SFP motuhake (GPON, XGS-PON, 25G-PON rānei). He ahurei ēnei nā te mea he BiDi (Bidirectional) simplex SFPs—e whakamahi ana i te hononga SC kotahi hei tuku i runga i te roangaru kotahi (hei tauira, 1490nm) me te whiwhi i runga i tētahi atu (hei tauira, 1310nm) hei mahi ki te 32, ki te 64 rānei ngā kāinga i runga i te kotahi miro muka. Te Whakapakari Ahumahi: Me whai pāmahana Ahumahi (-40°C ki te 85°C) ngā SFT e whakatakotoria ana ki runga i te pourewa kia ora ai i ngā huarere tino kino o te wā. Ka whakauruhia ki roto i ngā whare pakari o waho pēnei i a FullAXS, ODVA rānei i mua i te mono tika atu ki te Wāhanga Reo Irirangi Mamao (RRU).
Taha ONT/ONU: He maha ngā wā ka whakamahia e te whatunga whatu taha-kiritaki i roto i te kāinga, i te pakihi rānei ngā kōwae 1G SFP paerewa, 10G SFP+ rānei kua monohia ki te kuwaha kāinga. BiDi me te CWDM: Hei penapena i te taumaha me ngā rauemi muka i runga i te rawa pourewa, he maha ngā wā ka whakamahia e ngā tohunga hangarau ngā kōwae BiDi SFP28, CWDM SFP28 rānei, kia iti ake ai ngā aho karāhe e tohatohahia ana e ngā roopu auau maha.
Te Whakamahinga QSFP (Te Matua o te Tari Matua: Kāore ngā kaiwhakamahi kāinga e whakamahi i ngā kōwae QSFP. Engari, ka whakamahia ngā pūwhakawhiti QSFP28 (100G) QSFP-DD rānei (400G/800G) i roto i te Tari Matua. Ka kohikohia e rātou te nui o ngā waka e puta mai ana i ngā kāri raina PON SFP maha, ka tukuna ki runga ki te matua ipurangi whānui. Ngā Whakatakotoranga Pakaru: Engari mō te whakahaere i ngā taura SFP takitahi e 24, ka whakamahia e te pouara turanga matotoru-teitei ngā tauranga QSFP28 (100G) i te aratau pakaru. Ka honoa he tauranga QSFP28 kotahi ki te taura pūtake MPO pakaru 1-ki-4, ka tuku pai i ngā hongere eCPRI 25G motuhake e whā tae atu ki ngā reo irirangi pourewa motuhake e whā.

Tukanga
Tukanga
Tukanga